Boiler not firing up after summer: what to check first (London)

  • Checked September 2026
  • 4 min read
  • By PROS AI editorial team
Boiler not firing up after summer: what to check first (London)

Quick answer

The short version, before the detail.

A boiler that will not fire on the first cold morning is usually stopped by something outside the boiler: a control still set for summer, low pressure, a switch that is off, or a lockout that needs one reset. Work through the checks below in order; none of them opens the casing. If it still will not fire, book a Gas Safe registered engineer.

What is the likely cause?

Most common first. Each line says how to recognise it.

  1. Controls still on the summer setting: a combi left on hot water only, a timer that is off, a thermostat set below room temperature or with flat batteries.

    How to tell: the taps run hot but every radiator is cold.

  2. Low system pressure.

    How to tell: the gauge reads below 1 bar or sits in the red, with a low-pressure warning on the display.

  3. No power or no gas.

    How to tell: the display is dark (fused spur off, breaker tripped, prepayment electricity meter empty), or a gas hob will not light (prepayment gas meter empty).

  4. A lockout after a failed ignition.

    How to tell: a fault light or code is showing and the boiler is silent. One reset clears a one-off.

  5. Condensate not draining.

    How to tell: gurgling when the boiler tries to start, then repeated lockouts. In September the usual cause is an outside drain blocked with leaves or moss, not ice.

  6. A stuck diverter valve or pump.

    How to tell: hot water works but the heating never comes on, or the boiler fires briefly and stops. Valves can stick over time; this is engineer work.

  7. On an older boiler, a pilot light that has gone out.

    How to tell: no small blue flame where the manual says there should be one.

What can I safely check myself?

Every step here is done from the outside of the boiler. Nothing below opens the casing, removes a cover, or touches gas pipework or wiring.

  1. Controls. Put the boiler in heating mode (on a combi, not hot water only). Check the timer is on and shows the right time, because a power cut or the clock change can reset it. Turn the thermostat above room temperature and put fresh batteries in a wireless one.
  2. Power. Check the fused spur switch beside the boiler is on and its breaker on the consumer unit is up. The display should light.
  3. Pressure. Cool, the gauge should read 1 to 1.5 bar. Below 1 bar, open the filling loop until it reaches 1 to 1.5 bar, then close both valves fully. Below 0.5 bar, water has left the system and needs replacing before you try again.
  4. Reset once. Press the reset button for a few seconds (no more than ten) and wait two to three minutes. If it locks out again, do not keep pressing; a boiler that needs regular resets has a fault.
  5. Gas. Check another gas appliance lights, and top up a prepayment gas meter if you have one.
  6. Condensate pipe. Find the white plastic pipe where it leaves the wall outside and check the drain it feeds is clear of leaves. In a freeze, thaw it with warm, not boiling, water and reset once.
  7. Water. Run a cold tap. If nothing comes out, check the stopcock is open.

When do I stop and call an engineer?

  • If you smell gas, leave the property, do not switch anything on or off, and call the National Gas emergency line on 0800 111 999 from outside.
  • If water is dripping near the fused spur, sockets or the consumer unit, switch off at the main switch only if it is dry and safe to reach; otherwise keep away from it.
  • Stop if the boiler locks out again after a reset, if the pressure falls again within days, if the pump is noisy or hot, or if a pilot light will not stay lit. These are internal faults.
  • Anything behind the casing is gas work and must be done by a Gas Safe registered engineer. Ask for the ID card and check the seven-digit licence number on gassaferegister.co.uk, or text Gas and the number to 85080.

What does it cost in London?

A weekday call-out with diagnosis in London is £60 to £125, typically £120, and many firms waive it if the repair goes ahead. Labour is £80 to £140 an hour. Parts behind a no-fire fault run from £120 to £280 for a pressure or valve fault to £200 to £420 for a fan and £290 to £650 for a circuit board; most repairs land between £150 and £400 with the part.